Premium LiFePO4 Battery with BMS
- Over Current Protection
- Short Circuit Protection
- Over Charge Protection
- Over Discharge Protection
- Over Voltage Protection
- Thermal Protecion
DIFFERENT APPLICATIONS
RVS CAMPER VAN LIFE
Higher capacity and power output, and provides reliable and consistent power output to meet the energy demands of various RV systems.
HOME BACKUP OFF-GRID LIVING
Reap the benefits of lower energy costs and greater energy storage efficiency. Rack Mountable for quick and easy installation.
TROLLING MOTOR BATTERY
No Maintanence, no Leaking. Our lithium iron phosphate deep cycle battery provides slow steady power, 2X lighter, 4X lifespan.
Mechanical Specifications |
|
Case Material | ABS |
Cell Type-Chemistry | Prismatic LiFePO4 |
Terminal Type | M8 |
IP Grade | IP65 |
BMS Characteristics |
|
Recommended Charge Current | 50A |
Maximum Charge Current | 100A |
Maximum Continuous Discharge Current | 100A |
Recommended Charge Voltage | 13.6~13.8V |
Max Charge Voltage | 14.6V |
Overcharge Protection Voltage | 14.8~15.2V |
Charge Mode | CC/CV |
Discharge Cut-off Voltage Range | 11.2V |
Basic Performance |
|
Nominal Voltage | 12.8V |
Nominal Capacity | 100Ah |
Standard Discharge Time | 100A@60min |
Energy | 1.28KWh |
IR | <= 15mΩ |
Self Discharge | <=2%/Month |
Cells | Square 100Ah |
Cycle Life | 4000 times(1C/1C) |
Size | 330*171*220 |
Weight | 11.0 |
Compliance |
|
Certifications | CE/UN38.3/UL1642/IEC62133 |
Transport Appraisal | UN3480,CLASS 9 |
Charge Performance |
|
Rated Charge Current | 50A |
Maximum Charge Current | 100A |
Rated Charge Voltage | 13.6~13.8V |
Charge Cut-off Voltage | > 14.8V(0.5~1.5S) |
Reconnect Voltage | <14.4V |
Balancing Voltage | <14V |
System Series | <=6 |
Discharge Performance |
|
Rated Discharge Current | 100A |
Pulse Current(<=5S) | 600A |
Rated Discharge Cut-off Voltage | >11.2V |
Minimum Discharge Cut-off Voltage | >10V |
Reconnect Voltage | >10.4V |
Short Circuit Protection | 200~600 μs |
Short Circuit Current | Approx. 1200A |
Temperature Performance |
|
Discharge Temperature | -20~60℃ |
Charge Temperature | 0~45℃ |
Storage Temperature | -5~35℃ |
High Temperature Cut-off | 65℃ |
Reconnect Temperature | 48℃ |
FAQs
1) Recommend to fully charge the batteries before parallel connection.
2) The voltage of the two batteries should be the same when connected in parallel (error range 0.1V).
3) The cable length between batteries should be the same.
1) The SOC of the two batteries should be the same (small errors allowed).
2) The cable length between batteries should be the same.
3) Do not use batteries in series or in parallel for more than 4 months
You can't connect lithium battery and lead-acid battery together, and different brands of lithium batteries cannot be connected, because the batch of cells is not the same.
Even if it is the same brand, If the purchase interval is more than 4 months, it is also not recommended to connect.
Because the energy decay between the cells is not consistent.
The charging operation temperature is 0℃~55℃ (32℉ ~131℉)
The discharge operation temperature is -20℃~60℃ (-4℉ ~ 140℉)
If the battery is above or below these temperature ranges, the BMS will turn on the cut-off protection.