- Description
- Specification
- Tech Q&A
- Reviews
Review of Aolithium Server Rack Battery From Influnencers
How To Set Up Communication with Inverter?
Here are guidance to setup battery communications with EG4 3kw inverter and EG4 6000xp inverter.
Compatible With 20 Types of Inverters
Aolithium server rack batteries are compatible with Pylontech, GoodWe, Deye, Megarevo , Victron and 20 other inverters. For parallel communication operation of multiple server rack batteries, dial-up address configuration is required. Our server rack batteries meet address 16, address 32, address 48.
We only make the high-quality server rack battery.
BATTERY PACK
- Grade A Battery Cells
- Reliable 100A Built in BMS
- 16*3.2V 100Ah Prismatic Cells
(View prismatic cell advantages)
CYCLE LIFE
- 4000+ Cycles @90% DOD
WATERPROOF/CORROSION-PROOF
- 6.0 Single pole angled connector (IP67), salt spray rating 144H
LIFESPAN
- 15+ Years Lifespan
More Comprehensive Certifications
Aolithium server rack batteries are the most fully certified batteries on the market. In addition to the required UL listing, we also carry UN38.3/ Class 9/ UN3480/ MSDS certification. This is the best battery safety guarantee.
Rare LCD Screen
The LCD screen will display the voltage, current, temperature and SOC of the server rack battery as it charges and discharges. You can see the battery status more visually without having to buy or use other tools to monitor it. Few vendors choose to use screens.
Compatible With 20 Types of Inverters
Aolithium server rack batteries are compatible with Pylontech, GoodWe, Deye, Megarevo , Victron and 20 other inverters. For parallel communication operation of multiple server rack batteries, dial-up address configuration is required. Our server rack batteries meet address 16, address 32, address 48.
Fearless of Extreme Weather
Our server rack batteries can operate well in extreme weather. With the protection of BMS, LiFePO4 batteries can be discharged normally even in extremely cold weather.
- Charging Temperature 32°F to 131°F
- Discharging Temperature -4°F to 140°F
- Storage Temperature: 14°F to 86°F
BMS With Equalization
- Single Cell Over-Voltage Protection
- Single Cell Under-Voltage Protection
- Battery Over-Voltage Protection
- Battery Under-Voltage Protection
- Charging & Discharge Over-Current Protection
- Output Short Circuit Protection
Not For Start-Up Application
- Do not use the battery for golf cart application.
- Can't be used as a starting battery.
Server Rack Battery Requirements Accessory List
Cables(AK01, AK02) and racks need to be purchased separately. Please select the number of cables you need according to the number of batteries purchased.
AK01 means long cables kit.
AK02 means short cables kit.
AK03 means racks.
SPCIFICATION |
|
Nomial Voltage | 51.2V |
Nomial Capacity | 100Ah |
Energy | 5120Wh |
Weight | 47+/-0.5KG |
Dimensions L*W*H | 488*578*177.8mm(With handle and fixed bracket) |
Waterproof level | IP43 |
Voltage Window | 43.2~57.6V |
Charge Cut-off Voltage | 57.6V |
Discharge Cut-off Voltage | 43.2V |
Max.Continue Charge Current | 50A |
Max.Continue Discharge Current | 100A |
Efficiency | ≥95% |
Internal resistance | ≤14mΩ |
Recommended SOC Working Range | 15%~95% |
Self Discharge | ≤3% Per Month |
Cycle Life | >4000(@25℃,90%DOD)/>10Years |
Charge Temperature | 0℃~55℃ |
Disharge Temperature | -20℃~60℃ |
Storage Temperature | -10℃~30℃ |
Storage Environment Humidity | 5%~95% |
Storage Altitude Requirement | ≤1000m |
Construction | 1P16S |
Shipping Classification | UN 38.3 | Class 9 | UN3480 | MSDS |
Cell Type | 16*3.2v 100Ah LiFePO4 |
FAQs
No. Individual cell data can be viewed by accessing the menu on the display. The inverter can also display individual cell parameters when the battery product is connected to the inverter.
We have software for monitoring battery products, which requires the connection of a matching commissioning tool. We can provide a monitoring software only for monitoring data, connected to a PC.
Individual cell data can be accessed via the display in the menu. At the same time the inverter can also display individual cell parameters when the battery product is connected to the inverter.
We have software for monitoring battery products that need to be connected to a matching debugging tool, and we can provide a monitoring software that is only used for monitoring data and is connected to a PC.
We use the original full-capacity battery cell, the battery cell factory can provide the original data.
We test the capacity to ensure that the product is full capacity. Due to the transportation time and long storage time, lithium batteries are characterized by the need to be placed for a long time to activate the performance of 3-5 times charge and discharge, after the activation of the performance of the capacity can meet the requirements of the product manual, the number of cycles can also be guaranteed.
When the power switch is closed, the standby display hibernation state, the power consumption of the BMS and display 2-3W, the self-consumption of the core every month 1%-3%, the above power consumption BMS will not record this part of the power consumption. So the SOC and current power display will not match the product storage, you need to disconnect the power switch.
The BMS suppliers we have used are Shenzhen Darren Hi-Tech Electronics Limited and Shenzhen Kesheng Power Technology Co.
You can use 60V/5A adjustable power supply. Li-ion battery product charging end pressure difference according to <350mv (0.5C times rate current), discharging end <400mv (0.5C times rate current) control; this standard can meet the requirements of cycling performance in the product manual, in order to further enhance the product can be used power, it is recommended to do equalization adjustment when the product power decay to 80%.
BMS and display power consumption 2-3W, BMS will not record this part of the power consumption when the product is stored, you need to disconnect the power switch, otherwise the self-consumption of the battery cell itself, as well as the self-consumption of the BMS and the display resting screen will not be reflected in the SOC, which will lead to power loss. And it needs to be recharged in time when the battery is low. Storage time>1 month, please make sure the product is fully charged and the power switch is disconnected.
This has to do with the communication protocol of the inverter. Please refer to the description in the product manualfor more communication protocols.
Kit AK01 provides the plug for the companion product power receptacle as well as the power harness.
Our products are capable of discharging 100Ah, but we recommend using the interval of SOC: 15%-95% to extend the service life; the system capacity is affected by the ambient temperature, the temperature needs to be controlled at 25±2℃;
There are differences in product cell models as well as technical designs, and our products cannot be mixed and matched with other products.
For a single battery pack and inverter connection, select kit AK01. seeproduct manualillustration for details.
The BMS is configured with a pre-charge circuit.
DIP switch position down, means the address bit OFF; DIP switch position up, pointing to ON, means the address bit ON. Seeproduct manualfor details.
The product power connection socket adopts anti-dumbing design, to avoid the user misuse, connecting the wrong accident. Other manufacturers' plugs cannot be adapted, we provide cable kits.
The current bracket fixed connection solution matches the home 5KW inverter, easy to disassemble and install, and the wiring harness is dummy-proof to avoid mishandling. If more output power is needed, the harness and connectors need to be upgraded to use a storage cabinet type, busbar solution.
We use automotive grade fuses, and the advantage is in the breaking capacity and vibration performance, which protects better than T-class.
1) Recommend to fully charge the batteries before parallel connection.
2) The voltage of the two batteries should be the same when connected in parallel (error range 0.1V).
3) The cable length between batteries should be the same.
1) The SOC of the two batteries should be the same (small errors allowed).
2) The cable length between batteries should be the same.
You can't connect lithium battery and lead-acid battery together, and different brands of lithium batteries cannot be connected, because the batch of cells is not the same.
Even if it is the same brand, If the purchase interval is more than 4 months, it is also not recommended to connect.
Because the energy decay between the cells is not consistent.
The charging operation temperature is 0℃~55℃ (32℉ ~131℉)
The discharge operation temperature is -20℃~60℃ (-4℉ ~ 140℉)
If the battery is above or below these temperature ranges, the BMS will turn on the cut-off protection.
The length of time it takes to charge a li-ion deep cycle battery depends on the type and size of your charging source.
For example, if your charger is 20 amps and you need to charge an empty battery, it will take 5 hours to reach 100%, if your charger is 50 amps and you need to charge an empty battery, it will take 2 hours to reach 100%.
Our batteries can of course be shipped to Canada and Europe, there will just be some additional VAT in Europe. You can purchase directly from our website and VAT will be calculated automatically.
The battery can be mounted on its side and will not affect the performance.
MORE QUESTIONS ABOUT YOUR OFF-GRID POWER SYSTEM? LEARN MORE FROM THE AOLITHIUM HELP CENTER!